Golden Sunflower recommends common problems and solutions in the work of unloaders:

1. The unloader motor does not start;

Solution: A. Check whether the motor is stuck; B. Check whether the wiring is correct.

卸料器

2. There is abnormal sound from the unloader;

Solution: A. Check whether the impeller and the interior are damaged. B. Check whether the bearing is damaged. C. Check whether the speed is too fast.

3. External leakage of the discharge medium (except for the normal discharge port, the lower end of the valve cover on both sides)

Unloader manufacturer Solution: A. Check whether the gasket is damaged. B. Check whether the shaft seal gas is properly connected.

卸料器厂家

4. The unloading of the unloader is not smooth;

Solution: A. Check whether the system is equipped with a better exhaust device. B. Check whether there is a bridging phenomenon on the top of the system.

5. The star unloader leaks too much.

Solution: A. Check whether the system pressure is normal. B. Check whether the material characteristics are consistent with the order agreement.

星型卸料器

 6. The conveying capacity of the unloader does not match the system;

Solution: A. Check whether the material characteristics are consistent with the order agreement. B. Check whether the impeller speed can be adjusted.

7. The unloader is difficult to run at low speed (frequency conversion motor)

Solution: Consider replacing the sprocket and try to use the high frequency range of the power supply.

The above is the content collected by the editor of Jiangsu Jinkuihua Machinery Manufacturing Co., Ltd. If necessary, please contact us. The company specializes in the production of quick cleaning valves, reducers, rotary valves, shut-off fans, shut-off fans, star dischargers, ash discharge valves, shut-off fans, dust removal equipment accessories, discharger manufacturers, electric air locks and other products; It is widely used in equipment in petrochemical, electric power, environmental protection, food, pharmaceutical, metallurgy, construction and other industries. It is an important part of dry dust removal equipment. It is especially suitable for solid particles, powder particles, and ultra-fine powders in pneumatic conveying and pipe networks. Feeding and unloading under positive and negative pressure. The company is located in Changzhou City, the economically developed Yangtze River Delta, with beautiful scenery and convenient transportation. We provide customers with high-quality products and high-quality services, and sincerely work with you to advance hand in hand, cooperate with integrity, and create a better future!

Scan the QR code to read on your phone

Related News

What

What are the debugging skills of the rotary valve?

Rotary valves are widely used. So, what debugging skills does it have? I believe that many of my friends don’t understand this very well. Let me briefly introduce it to you, let’s take a look!
2021-02-18
Failure

Failure analysis of rotary valve

1. Why is there no sound or no sound after some rotary valves are welded? This situation may be due to the excessive power density of the soldering iron that can be used during the soldering process (20-30W soldering iron is recommended) or the time may be too long, causing the solder joints between the pins of the rotary valve and the coil to be heated and melted. 2. Why do some rotary valves have a low, silent or sandy tone after welding? This situation may be that the current to start the rotary valve is too small or too large, causing the rotary valve to fail to sound normally.
2021-01-24
Tips

Tips for maintaining rotary valves in winter

How to maintain the rotary valve in winter? Do friends understand? Let’s take a look with the editor!
2021-01-16
Do

Do you know the rotary valve?

In some equipment, there is a component used to control the in and out of materials, which can be fully automatic or manually controlled. Rotary valve is one such part. Rotary valve is also called shut-off fan. Although they have different names, they are actually one thing. Let’s take a look with the editor below!
2021-01-12

Online Message

Username used for comment:
客户留言
Description:
验证码

Site navigation

金葵花

Home               News
Products           About Us
Honor               Contact

Contact Us

金葵花
jkh

Tel:0519-86482636

Mail:jkh@jsjinkui.cn

Address: Xvebu Town, Wujin District, Changzhou City, China​

JINKUIHUA

Follow us

金葵花
  • jkh

    Mobile website

  • jkh

    Wechat

Changzhou  Jinkui Machinery Manufacturing Co., Ltd.  苏ICP备19034381号-1     www.300.cn