Common faults and improvement measures of turning off the fan

Common faults and improvement measures of turning off the fan

  • Categories:Industry News
  • Author:金葵花
  • Origin:www.jsjinkuihua.cn/
  • Time of issue:2021-03-01
  • Views:0

(Summary description)Turn off the fan, usually used as the main equipment for dust removal equipment, air supply and other equipment feeding. Suitable for powder and granular materials. It is widely used in environmental protection, metallurgy, chemical, food, food and other industrial sectors. Let us understand common failures and improvement measures.

Common faults and improvement measures of turning off the fan

(Summary description)Turn off the fan, usually used as the main equipment for dust removal equipment, air supply and other equipment feeding. Suitable for powder and granular materials. It is widely used in environmental protection, metallurgy, chemical, food, food and other industrial sectors. Let us understand common failures and improvement measures.

  • Categories:Industry News
  • Author:金葵花
  • Origin:www.jsjinkuihua.cn/
  • Time of issue:2021-03-01
  • Views:0
Information

Turn off the fan, usually used as the main equipment for dust removal equipment, air supply and other equipment feeding. Suitable for powder and granular materials. It is widely used in environmental protection, metallurgy, chemical, food, food and other industrial sectors. Let us understand common failures and improvement measures.

The common faults that Golden Sunflower recommends to turn off the fan are:

1. Turning off the fan is suitable for continuous work, allowing forward and reverse operation.

2. When the output shaft, input shaft and other parts of the discharger are accessories, direct, hammering and damage are not allowed.

3. During the transportation and installation of the fan, the fan should be stable to avoid collision and cause the shell to crack and deform.

关风机

4. During operation, avoid overloading operation of equipment due to large material particles and strong adhesion, or avoid equipment blockage or motor short circuit or equipment damage due to foreign matter and equipment in the dust collector. It is recommended that users check and install overload protection devices in time.

5. During use, if the equipment leaks air or dust along the axial direction, the gland can be firm.

6. Before the air shutter leaves the factory, the reducer has been filled with 00 lubricating oil, and the dust discharge valve has been filled with lithium base grease. Transmission and bearing parts should be refilled with grease or replaced with grease within 6-10 months after use. If the ambient temperature is high, humid or there is too much dust in the air, the oil change time should be shortened appropriately.

关风器

  Improved knowledge of turning off the fan:

1. In order to prevent the ash at both ends of the impeller from entering the bearing due to severe bee leakage, the lower volume of the impeller end is increased with an ash discharge groove; to prevent poor lubrication of the bearing due to high temperature, the bearing box is replaced with an external bearing box.

2. In order to prevent foreign matter from falling into the silo and blocking the unloader impeller and burning the motor, please use a dry overload protection clutch instead of the safety pin in the previous product.

3. An inspection hole is installed on the side of the housing above the impeller.

4. There are two kinds of driving devices, gear difference planetary reducer and cycloid pinwheel reducer, which can be selected according to needs.

5. The impeller and the end cover, the dynamic and static connection parts adopt alloy wear-resistant sleeves.

6. The fan is usually not equipped with a manual gate valve, which is convenient for maintenance, troubleshooting and replacement.

7. The impeller is equipped with rubber skin to prevent dust from squeezing into the bearing and blocking large particles.

Scan the QR code to read on your phone

Related News

What

What are the debugging skills of the rotary valve?

Rotary valves are widely used. So, what debugging skills does it have? I believe that many of my friends don’t understand this very well. Let me briefly introduce it to you, let’s take a look!
2021-02-18
Failure

Failure analysis of rotary valve

1. Why is there no sound or no sound after some rotary valves are welded? This situation may be due to the excessive power density of the soldering iron that can be used during the soldering process (20-30W soldering iron is recommended) or the time may be too long, causing the solder joints between the pins of the rotary valve and the coil to be heated and melted. 2. Why do some rotary valves have a low, silent or sandy tone after welding? This situation may be that the current to start the rotary valve is too small or too large, causing the rotary valve to fail to sound normally.
2021-01-24
Tips

Tips for maintaining rotary valves in winter

How to maintain the rotary valve in winter? Do friends understand? Let’s take a look with the editor!
2021-01-16
Do

Do you know the rotary valve?

In some equipment, there is a component used to control the in and out of materials, which can be fully automatic or manually controlled. Rotary valve is one such part. Rotary valve is also called shut-off fan. Although they have different names, they are actually one thing. Let’s take a look with the editor below!
2021-01-12

Online Message

Username used for comment:
客户留言
Description:
验证码

Site navigation

金葵花

Home               News
Products           About Us
Honor               Contact

Contact Us

金葵花
jkh

Tel:0519-86482636

Mail:jkh@jsjinkui.cn

Address: Xvebu Town, Wujin District, Changzhou City, China​

JINKUIHUA

Follow us

金葵花
  • jkh

    Mobile website

  • jkh

    Wechat

Changzhou  Jinkui Machinery Manufacturing Co., Ltd.  苏ICP备19034381号-1     www.300.cn